When a rise is too tall or a site too tight for a ramp, a vertical platform lift, stair lift, LULA elevator, or residential elevator becomes the accessible route. Grandview builds the hoistway, pit, structure, and power the lift needs and manages licensed elevator contractors who install the device, all under one B100-licensed contract.

Discuss a project   Or call (385) 236-1741

Multi-level commercial atrium where an elevator or platform lift connects the public floors

When a lift is the right answer instead of a ramp

Ramps are cheaper, simpler, and need no service contract, so we start there. The math decides it: at 1:12, a 6-foot level change wants 72 feet of ramp plus landings. On a downtown Provo storefront with eight feet of sidewalk, or a split-level home with a half-flight between garage and kitchen, that ramp does not exist. That’s when a lift earns its place.

Platform lifts are allowed in new construction only for a short list of situations, but they’re broadly accepted in existing buildings as part of an alteration’s accessible route, which is where most Utah lift projects sit. If the rise is under about 30 inches and there’s room, read wheelchair ramp construction instead; if the barrier is a threshold or door, start with accessible entrance upgrades. A lift fixes vertical travel; the route to and from it still has to work on both landings.

Which device fits which building

  • Vertical platform lift (VPL). An open or enclosed platform travelling straight up, a few feet to about fourteen. The workhorse for commercial entrances, stages, and porches. Needs a shallow pit or ramped entry on a firm, level slab.
  • Inclined platform or stair lift. Rides a rail on the stair stringer or wall. No pit, no shaft; the stair must keep its clear width with the unit parked. Stair chair lifts suit one user at home, not the public.
  • LULA elevator. A limited-use, limited-application elevator for small commercial buildings: a real car and hoistway with a smaller footprint and pit than a passenger elevator. Common in churches, clinics, and two-story offices.
  • Residential elevator. Hydraulic, traction, or pneumatic. Pneumatic tubes skip the pit; the others want a pit, overhead clearance, and often a machine closet.

Licensed elevator contractors supply and install every one of these devices; Grandview does not install elevators. We hold the contract, select the device with you and the installer early, build everything it arrives into, and coordinate, sequence, and quality-check the installer’s work. The device is the easy part to buy. The building around it is where things go wrong.

What Grandview builds around the lift

  1. Get the installer’s drawings first. Every manufacturer publishes a site-prep sheet: pit depth, plumb tolerance, rail-bracket spacing, overhead clearance, load reactions. We build to that sheet, and we get it before demolition starts.
  2. Pit and slab. Residential units and LULAs usually want a pit under about fourteen inches; passenger elevators want several feet. We form and pour it with waterproofing and a sump where groundwater or a summer cloudburst could find it. On collapsible bench soils or expansive clay the pit gets a prepared subgrade and site-sized footings, because a rail that drifts out of plumb when the slab moves is a service call that never ends.
  3. Hoistway framing and structure. Steel or wood framing to the installer’s plumb tolerance, with blocking or steel at each rail-bracket elevation to take the reaction loads. Multi-story commercial shafts generally need rated enclosure, and along the Wasatch fault the rail anchorage is designed for seismic loads and inspected.
  4. Power and communication. A dedicated circuit and disconnect, pit light and outlet, and the two-way emergency communication the code requires. Grandview manages licensed electricians for this and sequences their rough-in with the installer.
  5. Permits on two tracks. The pit, hoistway, and structure go through the city building permit. Elevators and lifts in Utah commercial buildings are also permitted and inspected at the state level through the Labor Commission’s elevator safety program, filed by the installer, and the device can’t carry passengers until that inspection passes.
  6. Finish and hand over. Landings, gates, finishes, controls at reach range, and one binder with as-builts, the inspection certificate, and the maintenance paperwork. Exterior lifts get a lower landing in air-entrained concrete with drainage that works through Utah’s hundred-plus freeze-thaw days, so meltwater never freezes the platform in place.
New framing inside an existing house during a renovation, the kind of structure a residential elevator hoistway is built into

What does a wheelchair lift installation cost in Utah?

As ballpark planning numbers, not quotes: a vertical platform lift at an existing commercial entrance commonly lands between $15,000 and $40,000 once pit, landing, power, and enclosure are counted. A LULA elevator with its hoistway is often $75,000 to $150,000. Residential elevators typically run $40,000 to $100,000 or more, roughly half device and half construction. A site visit turns these into a real proposal.

  • Pit depth and what’s under it. A pit over clay, fill, or a high water table adds waterproofing, drainage, and subgrade work.
  • Hoistway in an existing building. A new shaft means cutting floors, reframing openings, and rated walls in commercial work, often while the building stays open. A VPL at an exterior entrance avoids nearly all of that.
  • Travel, weather, and service. Each extra landing adds a door and interlock; outdoor lifts want an enclosure and heater; every commercial lift carries inspection and maintenance obligations a ramp never will.

Sometimes a longer ramp on a reworked site beats a lift on lifetime cost. We’ll say so before you buy the device.

Indoor staircase with metal railings, the kind of straight run an inclined platform lift or stair lift mounts to

Questions we actually get

Can a platform lift count as my ADA accessible route?

In an existing building being altered, generally yes; platform lifts are an accepted part of an accessible route under the 2010 ADA Standards. In new construction they’re permitted only in specific situations, so a new building usually needs a ramp or elevator. An ADA compliance survey settles which case applies before any device is ordered.

Who inspects the lift once it’s installed?

Two parties. The city inspects the construction, meaning pit, hoistway, structure, and electrical, under the current Utah-adopted code. The state inspects the device through the Utah Labor Commission’s elevator safety program before it carries passengers, and commercial units are re-inspected periodically. Private-home rules differ, so verify residential requirements with the Labor Commission.

Does earthquake risk change how the hoistway is built?

Yes. Much of the Wasatch Front sits near the Wasatch fault, and elevator rail brackets, counterweight restraints, and hoistway anchorage are designed for seismic loads accordingly. The practical effect is more steel and more inspected connections in the shaft, which we plan into the structure rather than discover when the installer’s engineer asks.