Fire-rated door installation in Salt Lake City
Fire-rated door installation is the fitting of a labeled door, frame, and hardware as one listed assembly — the 20-minute door between garage and house, apartment corridor and stair doors, or 90-minute openings in a commercial tenant separation. Grandview installs them across Salt Lake County and Utah County under a B100 general contractor license, set to the clearances and hardware that let the label hold up at inspection.

When a rated door is what the opening actually needs
A fire-rated door belongs wherever code draws a line between spaces that must not share a fire: garage to house, unit to corridor, corridor to exit stair, tenant to tenant. The tell is usually a correction notice, a plan-review comment, or a hollow-core door someone hung in a rated frame twenty years ago. If the opening sits in a rated wall, the door is a life-safety component, not a finish item.
A fiberglass front door is an entry door and carries no rating. Bedroom and closet doors are interior doors. An aluminum-and-glass retail entrance is a storefront door, and the overhead door on the garage itself is a garage door — neither is rated. A rated door only works inside a rated wall, which is why it often travels with fire-rated drywall. The rest of the scope lives on our window and door installation page, inside the site, structure & envelope family.
What’s in a listed fire door assembly
The rating belongs to the assembly, not the slab. The door carries a UL or Intertek label — 20, 45, 60, 90, or 180 minutes — that must stay legible and unpainted. Residential work is mostly 20-minute mineral-core wood or steel; corridor and stair openings run 60 to 90 minutes in hollow metal.
The frame is labeled too: a labeled wood jamb for a garage door, or a 16-gauge hollow metal frame with anchors matched to the wall — masonry wire anchors, steel-stud anchors, or existing-opening anchors for retrofits.
The hardware is where most rated doors fail inspection: ball-bearing steel hinges, a listed closer or spring hinges so it self-closes, and positive latching that holds under pressure. Wedges are out; a corridor door that must stay open gets a listed electromagnetic hold-open released by the fire alarm, which we coordinate with the licensed fire alarm contractor on the job.
Glazing and seals must match: ceramic fire-rated glass in a listed vision-lite kit, plus an “S”-labeled smoke gasket on doors that also serve as smoke barriers — standard on apartment unit entries.

How we install a rated door so it keeps its listing
- Confirm the required rating. We read it off the approved plans or the wall’s assembly listing, not off the old door, and verify the wall itself is rated.
- Order a matched assembly. Door, frame, hinges, closer, latch, glazing, and gasket come from one submittal so every component is listed for the rating. Hollow metal lead times run several weeks, so this order goes in early.
- Set and anchor the frame. Plumb, square, and level, anchored per the listing; grouted in masonry, packed with mineral wool rather than foam in stud walls.
- Hang and set clearances. NFPA 80 governs the gaps: roughly an eighth of an inch at head and jambs and no more than three-quarters of an inch at the floor. We don’t trim a rated slab to fit a bad opening — we fix the opening.
- Hardware and function test. Released from full open and from a few inches open, the door must close and latch on its own both times. Label visible, gasket seated, strike adjusted.

Where rated doors show up along the Wasatch Front
Garage to house. Current Utah-adopted code requires the door between an attached garage and living space to be solid wood or solid- or honeycomb-core steel at least 1-3/8 inches thick, or a 20-minute rated door, self-closing and self-latching — verify specifics with your city’s building department. One local wrinkle: garage slabs over expansive clay on bench lots in Draper, Alpine, and east Provo can heave at the threshold and close the bottom clearance, so we check the slab before setting frame height.
Multifamily. Unit entry, corridor, and stair doors are rated and gasketed, and the fast-growth apartment corridors of Lehi and Saratoga Springs put a lot of them on one inspection list. On occupied buildings we replace them one at a time so no unit is open to the corridor overnight.
Commercial. Tenant separations, mechanical rooms, exit passageways. Utah’s adopted fire code references NFPA 80’s annual inspection of fire door assemblies; a fail usually comes down to a missing closer or a painted-over label, both cheap to fix before the fire marshal visits.
What a fire-rated door costs in Utah
As a ballpark planning range, a 20-minute garage-to-house door with labeled frame, closer, and installation usually lands in the high hundreds to low thousands. A commercial hollow metal door, welded frame, listed closer, and lever lockset typically runs low-to-mid thousands per opening installed, climbing with panic hardware, rated vision glass, electrified hold-opens, or a frame cut into existing masonry. Planning numbers, not a quote.
What moves the number: the rating required; hollow metal versus wood; hardware tier and any access-control tie-in; glazing; whether the existing opening is square; and quantity. The license behind the work is verifiable at DOPL.
Questions we actually get
Can I just put a closer on my existing door and call it rated?
Only if the door and frame already carry a legible rating label. A closer makes an unrated door self-closing, which satisfies one requirement, but adds no rating. No label on the door edge and frame means the honest fix is a labeled assembly — for a garage-to-house opening, a modest job.
Can a fire-rated door be trimmed to fit my opening?
Barely. NFPA 80 limits field modifications to small amounts in specific locations, and anything beyond that voids the label. In practice we size the door to the frame and fix the opening to suit the frame, rather than cutting a rated slab down to meet a crooked jamb.
Can a rated door have a window in it?
Yes, within limits. The glass must be fire-rated — ceramic or listed wired glass — in a listed vision-lite kit, and the allowed glass area shrinks as the rating goes up: a 20-minute door can carry a large lite, a 90-minute door only a small one. We specify the kit with the door so the label covers it.
What drives the cost between a 20-minute and a 90-minute door?
Core construction, frame gauge, and hardware. A 20-minute wood door in a labeled wood jamb costs close to an ordinary pre-hung door. A 90-minute hollow metal door needs a heavier frame, a listed closer, and more anchoring, and usually sits in commercial or multifamily walls that take more labor to open and patch.
Tell us what you’re working on
We reply within a couple of hours during business hours — a day at most. You’ll get a straight read on scope, sequence, and budget before anyone commits to anything.