Renovation & Build-Outs · Insulation

Blown-In & Loose-Fill Insulation in Utah County

Blown-in insulation is loose fiberglass or cellulose fed through a hose and blown into an attic floor or an enclosed cavity until it reaches a measured depth. It is the right choice for open attics, odd-shaped joist bays, and any space where cutting batts to fit would leave gaps — and Grandview Contractors installs it across Utah County and Salt Lake County under a Utah DOPL B100 general contractor license.

Discuss a project   Or call (385) 236-1741

Exposed wood ceiling joists and beams in an attic space before loose-fill insulation is blown in
When it’s the right call

When blown-in beats batts, foam, or dense-pack

Loose-fill wins wherever the cavity is irregular, the access is from above, or the budget has to stretch across a large area. A typical attic floor is crossed by wiring, plumbing vents, truss webs, and ductwork. Batts must be cut and tucked around each obstacle; blown-in flows around them. That is why the attic top-up on most Wasatch Front homes is a blown-in job, not a batt job.

Where it isn’t the first pick: an open wall with clean, regular stud bays is often cheaper to fill with fiberglass batts. A rim joist, a cathedral ceiling, or any place you need an air barrier and insulation in a single material is spray foam territory. And a closed wall with drywall already on both sides calls for dense-pack — the same loose material, but packed under pressure through drilled holes rather than loosely blown. Different jobs, different machine settings, priced as such.

Blown-in is also what most Utah attics already contain. In homes built before the mid-1990s, the existing layer has often settled to half its original depth. Topping it up is routine; it only comes out if it is wet, rodent-damaged, or vermiculite.

The work

What a blown-in installation involves

  1. Measure what’s there. We probe the existing layer at several points, note the material, and check the sheathing for moisture staining. Four inches of settled fiberglass is roughly R-11, well short of the R-49 and up that current Utah-adopted energy code expects in climate zone 5.
  2. Seal the ceiling plane. Top plates, wire and pipe penetrations, bath-fan housings, and the attic hatch get foam or caulk before any material goes in. Wind moves air through loose fill more readily than through a dense batt, which is why our air sealing work is sequenced first.
  3. Dam and baffle. Rigid baffles go in at every eave bay so soffit air still reaches the ridge, and blocking goes around the hatch, chimneys, and any recessed lights that aren’t rated for insulation contact. Without these, loose fill slumps into the soffits and the roof stops ventilating.
  4. Blow to a marked depth. Cardboard depth rulers get stapled to trusses across the attic. The machine is set for the chosen material and we blow in passes until every ruler reads the target — typically 14 to 16 inches of fiberglass or 12 to 14 of cellulose for an R-49 finish, depending on the product’s coverage chart.
  5. Document. You get photos of the rulers, the bag count, and the coverage chart for the installed product. That record is what an energy auditor or a future buyer will want to see.
Roof trusses and loft framing where eave baffles and depth markers are set before blowing in loose-fill insulation
Materials

Fiberglass or cellulose: which loose fill to blow

Both reach the same R-value by different routes. Blown fiberglass is lighter, does not absorb water, and barely settles — the default for attics with a history of roof leaks or thin ceiling drywall. Blown cellulose is borate-treated recycled paper: denser, quieter, better at slowing air per inch, and usually a little cheaper per installed R-value. It settles a few percent in the first year, so the coverage chart calls for a deeper initial pour. The U.S. Department of Energy’s material comparison covers the trade-offs in more detail.

Two Utah factors tip the choice. On bench lots and in canyon-mouth communities like Alpine or the Draper foothills, wind pressure across the attic favors cellulose or a cellulose top layer — loose fiberglass can be scoured thin at the eaves in a strong canyon-wind event. On the valley floor, where roofs carry snow for weeks, ice damming is the bigger worry, and the priority is a sealed ceiling plane under either material so warm air never melts the snow from below.

Budget

What does blown-in insulation cost in Utah?

As a planning ballpark, not a quote: blowing a typical Utah County attic from a settled layer up to R-49 usually lands between the high hundreds and the low thousands, air sealing and baffles included. Cost per square foot falls as the attic grows, because machine setup is a fixed cost either way.

What moves the number up: attic access through a closet hatch rather than a garage pull-down, extensive can lights that need rated covers, a vermiculite layer that must be tested and professionally removed before anything else happens, and leaky ductwork worth sealing while we are up there. What moves it down: a walkable attic, a recent roof with sound sheathing, and bundling the work with a renovation that already has us on site. ENERGY STAR’s seal-and-insulate guidance is a reasonable check on whether the recommended depth for your zone matches what you’re being quoted.

Two-story home with a snow-covered roof, the kind of winter load that makes a sealed, deeply insulated attic matter in Utah

Questions we actually get

Can you blow new insulation over the old layer?

Usually, yes. Dry, intact fiberglass or cellulose stays and gets topped up. We remove it first if it is wet, moldy, heavily rodent-contaminated, or if it is vermiculite, which may contain asbestos and must be tested before anyone disturbs it. We check for all of that during the inspection, not after the truck is loaded.

How deep should blown-in insulation be in Utah?

For an R-49 attic, plan on roughly 14 to 16 inches of blown fiberglass or 12 to 14 inches of cellulose, per the manufacturer’s coverage chart. Climate zone 5 covers most of Utah County and Salt Lake County. Existing settled material counts toward the total, so a four-inch layer needs about ten to twelve inches added, not the full depth.

Will blown-in insulation cover my recessed lights or attic storage?

Recessed lights rated IC can be covered; older non-IC cans need a fire-rated cover or a clearance box first. Storage areas need a raised platform above the finished depth, or that section stays thin. We flag both during the walkthrough.

How long does the job take?

Most single-family attics are a one-day job: air sealing and baffles in the morning, blowing in the afternoon. Large or badly leaky attics, or ones needing old material vacuumed out, run two days. The hose runs in through a window or the garage, so the house stays livable and the mess stays outside.

Tell us what you’re working on

We reply within a couple of hours during business hours — a day at most. You’ll get a straight read on scope, sequence, and budget before anyone commits to anything — including whether blown-in or another insulation option fits your attic.

Request an estimate   (385) 236-1741